CoolMaster 1000D Daikin VRV

Control and Monitor Daikin VRV Air Conditioning Systems


Overview


CoolMaster 1000D is versatile bridge device connecting Daikin VRV Air Conditioning systems and any RS232 or USB capable device like Home PC, Embedded PC or Home Automation Controller. Exposing simple interface over RS232 communication line or USB bus, CoolMaster gains user application full control on indoor units and provides access to VRV system parameters. In other words CoolMaster hides complexity of internal Daikin Communication line (including very unique physical layer) and instead gives simple, comprehensive, well documented protocol running on popular RS232 or USB connection.

CoolMaster Usage Diagram

Features

CoolMaster Icon - Plug-n-Play

Easy to integrate with Home Automation Systems and PC applications

CoolMaster interface is very simple and straightforward. Implementation of software modules to support CoolMaster is not complex at all.

CoolMaster Icon - RS232

Unified RS232 Interface

All CoolMaster products impose unified RS232 interface. It means for example that home automation application working on Daikin VRV system with CoolMaster 1000D will work exactly the same way on Mitsubishi Electric VRV, Sanyo VRF, Toshiba VRF and other systems with CoolMaster 4000M, 3000T, 2000S. No special interface adaptation will be required to migrate from one CoolMaster type to another.

CoolMaster Icon - Full Control

Full Control over Indoor Units Operation

On/Off control, Cool, Heat, Fan, Dry mode selection, Set Temperature Control, Fan Speed Control, Swing Control (for wall mounted and cassette indoor units), Filter Reset Sign, Group Operations (All On, All Off).

CoolMaster Icon - Unit Monitoring

Outdoor and Indoor Units Monitoring

Failure Alarms, Set point temperature, Operation status (on/off) Operation mode (cool/heat/fan/dry), Fan speed (high/low), Filter sign, Swing.

CoolMaster Icon - Diagnostics

System Diagnostics (An option for advanced users)

Outdoor Units internal parameters: Condensing, Evaporation, Ambient Temperatures, EV Opening, System Power Consumption (current), Inverter Revolutions and others Indoor Units internal parameters: Return air, Gas and Liquid Temperatures, EV Opening.

CoolMaster Icon - Upgradeable

Field Upgradable

New Firmware can be uploaded via RS232 port. No need to open unit to change it's functionality.

CoolMaster Icon - feature

CoolMaster unit can be extended with additional Hardware modules

Up to 4-GPIO, RS485, MODBUS, C-Bus(under development).

Specification



Block Diagram

  • CoolMaster-Block Diagram

Compatibility



Daikin Model Compatibility list

  • Outdoor Unit Types

    • RXYQ-M/P (VRV II,VRV III)
    • RXYK (VRV)
    • RXYSQ-M/P (VRV Small)
    • RXY-M
    • RWEYQ
    • REYQ

    Indoor Unit Types

    • FXCQ
    • FXNQ
    • FXLQ
    • FXFQ
    • FXKQ
    • FXZQ
    • FXDQ
    • FXSQ
    • FXAQ
    • FXUQ
    • FXMQ
    • FXHQ
    • VKM
    • VAM
    Multi, Split and Sky Air systems will also be compatible when using D3 Net interfaces (KRP928 or DTA112)
    * if your required models are not listed, please consult with us by email.


Home Automation Systems


Documents


Support



  • FAQ

  • CoolMaster LCD FAQ

    Below is an example of information that can be reflected on CoolMaster LCD.


    In this example VRV system has 3 indoor units with external addresses 1.01, 1.02 and 1.03. You can gather following information looking at the CoolMaster LCD.

    Unit ON/OFF Set Temperature Fan Speed Mode Failure Code
    1.01 OFF (-) 18° High Cool U4
    1.02 ON (+) 20° Low Fan No (OK)
    1.03 OFF (-) 18° High

    The strange string U03 G03 A3 U4 means that there are 3 indoor units - U03 and 3 indoor units with preset external address - G03. Failure codes A3 and U4 were detected in system.

  • CoolMaster Integration with HAI Omni/Lumina

    Introduction

    HAI Omni and Lumina family controllers support two-way integration with CoolMaster RS-232 interface adapters for VRV and VRF air conditioning systems. The HAI controller can change the setpoints, operating modes, and monitor changes in these items and current room temperatures.

    Each indoor unit appears as a standard HAI thermostat and may be controlled as though it was a standard HAI thermostat.

    Installation

    The HAI controller connects to the CoolMaster adapter using an HAI Model 36A05-4 Serial Connectivity Adapter Kit. Set the Serial Function for the serial port on the HAI controller to “CoolMaster”.

    Alternately, the HAI 10A17-1 Serial Expander may be used to connect the CoolMaster adapter. In this case, a straight-through DB-9 male-to-female cable must be used between the HAI controller and the CoolMaster adapter. Set the Expander Type for the desired HAI expander address to “CoolMaster”.

    Each CoolMaster adapter supports multiple indoor units. The HAI controller supports multiple CoolMaster adapters connected through unique serial ports on the HAI controller. Adapter 1 is connected to the lowest numbered serial port set to “CoolMaster”; adapter 2 is connected to the next higher serial port set to “CoolMaster”; and so on.

    Each thermostat in the HAI controller can be assigned to an indoor unit on one of the CoolMaster adapters. The specific indoor unit is identified by the adapter number, system number, and indoor unit address.  The system number and indoor unit addresses are determined from the CoolMaster adapter and the AC system settings. Associate a thermostat in the HAI controller with a CoolMaster indoor unit through the HAI PC Access software. First, set the thermostat type for the thermostat to “Auto Heat/Cool”, “Heat/Cool”, “Heat Only”, or “Cool Only” as appropriate. Next, click on “Protocol Address” and in the resulting dialog box set the protocol to “CoolMaster” and enter the adapter number, system number, and indoor unit address.

    Operation

    Setting the system mode of the HAI thermostat to “heat”, “cool”, or “auto” will set the operation mode of the indoor unit accordingly and turn the indoor unit on. Setting the system mode of the HAI thermostat to “off” will turn the indoor unit off.

    Setting the HAI thermostat fan mode to “auto” will set the indoor unit fan speed to low. Setting the fan mode to “on” will set the indoor unit fan speed to high. If the indoor unit is off, setting the fan mode on the HAI thermostat will set the fan speed and set the indoor unit operation mode to “fan”.

    It is not possible to set the indoor unit operation mode to “dry” or to set the fan speed to anything other than “low” or “high”. The HAI thermostat system mode will show “auto” if the indoor unit operation mode is “auto”, “fan”, or “dry”. The HAI thermostat fan mode will show “auto” if the indoor unit fan speed is “low”, and it will show “on” for any other fan speed setting.

    The CoolMaster adapter utilizes a single setpoint for heating and cooling. Changing either the heat or cool setpoint of the HAI thermostat will control this single setpoint.

    HAI Controller Compatibility

    CoolMaster interface adapters are supported by HAI Omni IIe, OmniPro II, Lumina and Lumina Pro systems. The systems must be utilizing controller firmware 3.8 or later.

  • Getting Trace off for the offline AC System Analysis

    1. Connect CoolMaster to your PC via RS232 port
    2. Extract attached d3dump.zip, it will create D3dump folder with following content:
    3. cygwin1.dll d3dump.bat d3dump38400.bat d3ttm.bat d3ttm38400.bat x232.exe

    4. Go to D3dum folder
    5. Double click BAT file (suggested by CoolAutomation support) to run it.
    6. Specify RS232 port number on the prompt
    7. ComPort: 1

      You must specify RS232 port number the CoolMaster is connected to.

    8. Let the program to run. To terminate program press Ctrl-C
    9. Trace will be stored in log file like this one:
    10. x232-2010.10.01.130746.log

    11. Power reset CoolMaster

    What to do with a log?

    Log should be sent to CoolAutomation staff for analyzing.


  • Contact us for technical support issues

    Support Form

    Have a technical question? Please fill out this form and we will get in touch with you shortly.

Downloads


Firmware

zip Download firmware for CoolMaster 1000D, v.2.6.0 Release Date: 2011-12



Price: $0.00